Siemens Set CEMS CERT Continuous Emissions Monitoring System



Set CEM CERT is a standardized and certified continuous emission monitoring system. Set CEM CERT is suitable for use in many plants which need to comply with European legislation according to Directive 2010/75/EU, the Industrial Emissions Directive. The modular CEMS meets the current quality standards of EU directives EN 15267 and EN 14181. The number of components that need to be measured depends on the type of plant as well as the fuel used. The measurement of gas components takes place according to the cold-extractive measuring procedure. A sample flow is constantly being extracted for measurement purposes in the exhaust gas stack by means of a gas sampling probe and transported to the analysis cabinet. The modular design system cabinet can be equipped with up to three analysers and different sample preparation components.
The complete tested modular measuring system consists of the sampling probe, the heated sample gas line, a two-stage sample gas cooler, a gas pump and up to 3 gas analysers including: ULTRAMAT 23, ULTRAMAT 6, OXYMAT 6, LDS 6 and/or SIPROCESS UV600.
- Up to 3 analysers with different measuring ranges can be configured
- A Fidamat 6 can also be added in a separate cabinet to measure TOCs,
- Selection of versions for indoor or outdoor installation
- Selection of sample gas cooler and NOX converter from leading manufacturers
- Electric heaters and air conditioners can be configured to extend the ambient temperature range
- Selection of versions with appropriate sampling probes, heated sample gas lines
Analysers
ULTRAMAT 23
ULTRAMAT / OXYMAT 6
SIPROCESS UV600
Components:
Hydrogen fluoride (HF) + water, Hydrogen chloride (HCl) + water, Ammonia (NH3) + water, Water vapor (H2O), Carbon monoxide (CO), Carbon dioxide (CO2), Nobelium (NO), Nitrogen Dioxide (NO2), Nitrogen oxides (NOx), Sulfur dioxide (SO2), electrochemical or paramagnetic.
Application
- Emission monitoring of power plants fuelled with solid, gaseous or liquid fuels
- Emission monitoring of so-called TA air plants
- For plants in which corrosive aerosols (acid mist) may be encountered, suitable measures must be taken to remove the corrosive aerosols from the gas matrix. To do this, a project-specific technical clarification is required in advance.
- The tested measuring ranges can be selected for a variety of ranges to ensure use in different areas of application for the CEMS (checked for suitability according to EN 15267‑3: TÜV and MCERTS).
- The complete modular package allows the certified use of system components from different manufacturers (checked for suitability according to EN 15267‑3: TÜV and MCERTS).
- Simple and fast to configure
- Very low costs of procurement and operation Modular design
- Up to 3 analysers with different measuring ranges can be con figured
- Selection of sample gas cooler and NOX converter from leading manufacturers
- Electric heaters and air conditioners can be configured to extend the ambient temperature range
- Selection of versions with appropriate sampling probes, heated sample gas lines