Micronics U1000MKII-FM Fixed Clamp-on Flow Meter

The Ultraflo U1000MKII-FM is a transit time ultrasonic flow meter designed to work with clamp-on transducers, to provide accurate measurement of liquid flowing within a closed pipe, without the need for any mechanical parts to be inserted through the pipe wall or to protrude into the flow system. It takes just a few minutes to install and there is no need to shut down flow or drain the system!
- Measurement Technique: Ultrasonic, cross-correlation transit time method for flow measurement.
- Turn Down Ratio: 100:1
- Accuracy: ±1% – 3% of flow reading for >0.3m/s (1 ft/s).
- Flow Velocity Range: 0.1m/s – 10m/s (0.3 ft/s – 32 ft/s).
- Pipe Range: Available in 2 options. 22mm to 115mm and 125mm to 180mm
- OD. Note Pipe size is dependent on pipe material and internal diameter.
- Pipe Material: Steel, Stainless Steel, Plastic and Copper
- Water Temp Range: 0°C – 85°C (32°F – 185°F).
- Pulse Output: Pulse or Frequency. Pulse for Volume flow and Alarms.
- Frequency for flow rate. The pulse output can be configured as a loss of signal or low flow alarm. Opto-isolated MOSFET volt free contact (NO/NC).
- 4-20mA Output: Optional 4-20mA flow proportional output. Maximum load 620Ω.
- Modbus Communication: Optional Modbus RTU slave, RS485 serial link hardware layer. Modbus connection cable is 1m.
- External Power Supply: 12V – 24V ±10% AC/DC at 7 watts per unit.
- Optional plug in 12V power supply.
- Electronics Enclosure: IP54.
- Input/Output Cable: 5m x 6 core for power in, 4-20mA and pulse out.
- Dimensions: 250mm x 48mm x 90mm (10″ x 2″ x 4″) (electronics + guide rail).
similar products